MOELLER - P1-32/I2/SVB/N - Electrical Switches - ICDC-040913 - New
$54
$97.74
MOELLER – P1-32/I2/SVB/N – Electrical Switches – ICDC-040913 – New Main Category: Electrical | Sub-Category: Switches | Status: New Original Components MOELLER Part Number: P132I2SVBN | ICDC Internal Part Number: ICDC-040913 P1-32/I2/SVB/N Description: Product range Main switch maintenance switch Part group reference P1 Stop Function Emergency switching off function With red rotary handle and yellow locking ring Information about equipment supplied auxiliary contact fitted by user. Number of poles 3 pole N Auxiliary contacts 0 N/O 0 N/C Locking facility Lockable in the 0 (Off) position Degree of Protection IP65 Switching angle 90 ° Motor rating AC-23A, 50 – 60 Hz [P] 400 V [P] 15 kW Rated uninterrupted current [Iu] 32 A Note on rated uninterrupted current !u Rated uninterrupted current Iu is specified for max. cross-section. TECHNICAL DATA General Standards IEC/EN 60947, VDE 0660, IEC/EN 60204 Switch-disconnector according to IEC/EN 60947-3 Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Enclosed -25 – 40 °C Overvoltage category/pollution degree III/3 Rated impulse withstand voltage [Uimp] 6000 V AC Mechanical shock resistance 15 g Mounting position As required Contacts Mechanical variables Number of poles 3 pole N Mechanical variables Auxiliary contacts 0 N/O Mechanical variables Auxiliary contacts 0 N/C Electrical characteristics Rated operational voltage [Ue] 690 V AC Electrical characteristics Rated uninterrupted current [Iu] 32 A Electrical characteristics Note on rated uninterrupted current !u Rated uninterrupted current Iu is specified for max. cross-section. Load rating with intermittent operation, class 12 AB 25 % DF 2 x Ie Load rating with intermittent operation, class 12 AB 40 % DF 1.6 x Ie Load rating with intermittent operation, class 12 AB 60 % DF 1.3 x Ie Short-circuit rating Fuse 50 A gG/gL Rated short-time withstand current (1 s current) [Icw ] 640 Arms Note on rated short-time withstand current lcw Current for a time of 1 second Rated conditional short-circuit current [Iq] 80 kA Switching capacity cos ϕ rated making capacity as per IEC 60947-3 320 A Rated breaking capacity cos ϕ to IEC 60947-3 230 V 260 A Rated breaking capacity cos ϕ to IEC 60947-3 400/415 V 300 A Rated breaking capacity cos ϕ to IEC 60947-3 500 V 290 A Rated breaking capacity cos ϕ to IEC 60947-3 690 V 250 A Safe isolation to EN 61140 between the contacts 440 V AC Safe isolation to EN 61140 Current heat loss per contact at Ie 1.8 W Lifespan, mechanical [Operations] > 0.3 x 106 Maximum operating frequency [Operations/h] 1200 AC AC-3 Rating, motor load switch [P] 220 V 230 V [P] 7.5 kW AC AC-3 Rating, motor load switch [P] 400 V 415 V [P] 13 kW AC AC-3 Rating, motor load switch [P] 500 V [P] 18.5 kW AC AC-3 Rating, motor load switch [P] 690 V [P] 15 kW AC AC-3 Rated operational current motor load switch 230 V [Ie] 26.4 A AC AC-3 Rated operational current motor load switch 400V 415 V [Ie] 26.4 A AC AC-3 Rated operational current motor load switch 500 V [Ie ] 23.4 A AC AC-3 Rated operational current motor load switch 690 V [Ie] 14.7 A AC AC-23A Motor rating AC-23A, 50 – 60 Hz [P] 230 V [P] 7.5 kW AC AC-23A Motor rating AC-23A, 50 – 60 Hz [P] 400 V 415 V [P] 15 kW AC AC-23A Motor rating AC-23A, 50 – 60 Hz [P] 500 V [P] 18.5 kW AC AC-23A Motor rating AC-23A, 50 – 60 Hz [P] 690 V [P] 15 kW AC AC-23A Rated operational current motor load switch 230 V [Ie] 32 A AC AC-23A Rated operational current motor load switch 400 V 415 V [Ie] 32 A AC AC-23A Rated operational current motor load switch 500 V [Ie] 30 A AC AC-23A Rated operational current motor load switch 690 V [Ie] 19.8 A DC DC-1, Load-break switches L/R = 1 ms Rated operational current [Ie] 32 A DC DC-1, Load-break switches L/R = 1 ms Voltage per contact pair in series 60 V DC DC-23A, motor load switch L/R = 15 ms 24 V Rated operational current [Ie] 25 A DC DC-23A, motor load switch L/R = 15 ms 24 V Contacts 1 Quantity DC DC-23A, motor load switch L/R = 15 ms 48 V Rated operational current [Ie] 25 A DC DC-23A, motor load switch L/R = 15 ms 48 V Contacts 2 Quantity DC DC-23A, motor load switch L/R = 15 ms 60 V Rated operational current [Ie] 25 A DC DC-23A, motor load switch L/R = 15 ms 60 V Contacts 2 Quantity DC DC-23A, motor load switch L/R = 15 ms 120 V Rated operational current [Ie] 12 A DC DC-23A, motor load switch L/R = 15 ms 120 V Contacts 3 Quantity Control circuit reliability at 24 V DC, 10 mA [Fault probability] < 10-5,< 1 failure in 100,000 switching operations HF Terminal capacities Solid or stranded 1 x (1,5 – 6) 2 x (1,5 – 6) mm2 Flexible with ferrules to DIN 46228 1 x (1 – 4) 2 x (1 – 4) mm2 Terminal screw M4 Tightening torque for terminal screw 1.6 Nm Technical safety parameters: Notes B10d values as per EN ISO 13849-1, table C1 Rating data for approved types Terminal capacity Terminal screw M4 Terminal capacity Tightening torque 14.128 lb-in Contact us to discover P1-32/I2/SVB/N. ICDCSPARES.COM offers new or overhauled original components, ready in stock to be shipped via DHL Express! Call us! Check our Electrical section to discover more about ICDC catalog: a large selection of industrial spare parts including Fuses, Electric Motors, Switches and Switches. Are you looking for industrial Switches? ICDC offers online a wide selection of Switches of the most important OEMs like EATON, ABB and DANFOSS, besides MOELLER. ICDC, Your Industrial One Stop Shop for Components!
Switches